DCF77 RADIO RECIVER FOR CALIBRATION
59 €
Out of stock
DCF77 Radio Reciver for calibration of the Timegrapher CHR-9. Calibrating the internal quartz works via the comparison with the atomic clock in Mainflingen near Frankfurt. The time signal is broadcast over the radio signal. DCF77 is a longwave emitted over time signal. DCF77 is broadcast on the normal frequency of 77.5 kHz as time information in coded form. It has a range of about 2000 km around Frankfurt / Main or Mainflingen. In DCF77 signal the time information the next minute is coded. The DCF77 signal is the definition of the “right time” of Germany. The instrument is supplied calibrated. Once the measurements in comparable temperatures take place (for example, at the same room temperature), a new calibration is not necessary. ATTENTION! The reception of the signal is dependent on location and is outside Germany not guaranteed! The DCF77 receiver is not inevitably included and may have to be ordered.
DCF77 RADIOEMPFÄNGER ZUM KALIBRIEREN DER ZEITWAAGE
59 €
Out of stock
Mit einem optional erhältichen DCF77 Radioempfänger kann die Zeitwaage kalibriert werden. Zur Kalibrierung wird das Funksignal der Atomuhr in Mainflingen (DCF77) als Referenzsignal genutzt. Diese Kalibrierungsmethode ermöglicht eine Messgenauigkeit von wenigen Sekunden pro Jahr. Das Funksignal ist ortsabhängig und ist, zumindest theoretisch, im Umfang von 1000 km um Mainflingen bei Frankfurt am Main zu empfangen. Faktoren wie Landschaftsumgebung, Räumlichkeiten und das Wetter können das Signal stark beeinflussen. Wird das Gerät in stabiler Raumtemperatur betrieben, ist die Kalibrierung nicht notwendig.
ODBIORNIK RADIOWY DCF77 DO KALIBRACJI CHRONOKOMPARATORA
59 €
Out of stock
DCF77 Radio Reciver for calibration of the Timegrapher CHR-9. Calibrating the internal quartz works via the comparison with the atomic clock in Mainflingen near Frankfurt. The time signal is broadcast over the radio signal. DCF77 is a longwave emitted over time signal. DCF77 is broadcast on the normal frequency of 77.5 kHz as time information in coded form. It has a range of about 2000 km around Frankfurt / Main or Mainflingen. In DCF77 signal the time information the next minute is coded. The DCF77 signal is the definition of the “right time” of Germany. The instrument is supplied calibrated. Once the measurements in comparable temperatures take place (for example, at the same room temperature), a new calibration is not necessary. ATTENTION! The reception of the signal is dependent on location and is outside Germany not guaranteed! The DCF77 receiver is not inevitably included and may have to be ordered.